PA1000 Standby/Off power

General discussion

PA1000 Standby/Off power

Postby M1ICL » 03 Feb 2024 20:55

Hi

I have been using my PA1000 with my FTDX-10 but am planning to link it to my FTDX-5000.
I notice in the manual it states that when in Standby or switched off that 100W may be passed through the PA1000.
As the FTDX-5000 can output 200W would that cause a problem with the PA1000 in Standby or off?

Regards

Ian
M1ICL
M1ICL
 
Posts: 5
Joined: 19 Dec 2020 21:51
Location: England

Re: PA1000 Standby/Off power

Postby OH7SV » 17 Mar 2024 05:17

Ian,

I have tested only 100W but I don't see any problem with 200W thru PA1000 when it is STBY or power OFF.
The TRX connector is connected to ANT connector via T/R relay and a 100nF capacitor. See the attached simplified schematics.

Note. Be careful when switching PA1000 to OPER state - remember to reduce the drive power down to 10W.

Matti OH7SV
Attachments
pa1000-T-R-relay.jpg
User avatar
OH7SV
Moderator
 
Posts: 107
Joined: 11 Nov 2011 07:00
Location: Finland

Re: PA1000 Standby/Off power

Postby M1ICL » 17 Mar 2024 17:05

Great, thank you

Ian
M1ICL
M1ICL
 
Posts: 5
Joined: 19 Dec 2020 21:51
Location: England